For example depending on roof colour and orientation to the sun attic air temperatures can exceed 55 c 131 f when it is less than 38 c 100 f outside.
Attic ventilation requirements canada.
Most building codes require a ratio of 1 150 ventilation space to attic floor space.
Do not automatically increase ventilation.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
However in more extreme environments including much of canada during winter it can be a problem.
The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction.
In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq.
The following are the requirements taken directly from the irc.
The ratio of vent area to ceiling area should be approximately 1 to 300.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Although an airtight ceiling will significantly reduce the likelihood of moisture in the attic building codes still require minimum attic ventilation.
Air vent recommends 1 square foot of ventilation for every 150 square feet of attic floor space with half the ventilation represented by intake vents and half by exhaust vents such as ridge vents.
The majority of the requirements related to attic ventilation have not changed much from the previous editions.
2 where the roof slope is less than 1 in 6 or in roofs that are constructed with roof joists the unobstructed vent area shall be not less than 1 150 of the insulated ceiling area.
You can also contact your local municipality to check on building code in your area.
Of vent for every 300 sq.
Vent requirements 1 except as provided in sentence 2 the unobstructed vent area shall be not less than 1 300 of the insulated ceiling area.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
For minimum building code requirements use the 1 300 ratio instead of the 1 150 ratio.
Building codes vary.
These types of roofs therefore require more ventilation than common attic type roofs.